Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | P63X |
Relay Type | Transformer differntial Protection Relay |
Brand | Schneider |
Current | 1/5 A |
Voltage Type | DC |
Voltage (V) | 1A/5A |
Number Of Poles | 8 Poles |
Usage/Application | Transformer protection |
Type | Transformer Differential Protection Relays |
Available Models: (MiCOM MiCOM P631, MiCOM P632, MiCOM P633, MiCOM P634)
The MiCOM P63x series differential protection devices are intended for the fast and selective short circuit protection of transformers, motors, generators and other installations with two, three or four windings, respectively. The MiCOM P63x series provides high-speed three system differential protection using a triple-slope characteristic and two high-set differential elements in combination with transformer inrush restraint, overfluxing restraint and through-stabilization. Amplitude and vector group matching is done just by entering the nominal values of transformer windings and associated CTs.
Customer Benefits:
Multiple communication protocols and interfaces, including IEC 61850
CB Failure protection
Detachable HMI option
Application:
MiCOM P63x series differential protection devices provide a wide range of protection functions. The device selection depends on the protected object and the required protection scheme:
P630C: Two-end/winding schemes (two 3 pole CT inputs)
P631: Two-end/winding schemes (two 3 pole CT inputs)
P632: Two-end/winding schemes (two 4 pole CT inputs, one VT input)
P633: Three-end/winding schemes (three 4 pole CT inputs, one VT input)
P634: Four-end/winding schemes (three 4 pole CT inputs, one 3 pole CT input, one VT input)
Additional Information:
Product Details:
Relay Type | Protection Relay |
Brand | Schneider |
Voltage Type | AC/DC |
Number of Poles | 3 |
Auxiliary Voltage | 24-48 V |
Features:
Specification:
Product Details:
Voltage Type | AC/DC |
Voltage | 24 240 V AC / DC |
Current | 1-5 A |
Number of Poles | 3 Pole |
Application | Over-current & Earth Fault Protection |
Ct Ratio Programming | 1A or 5A |
Frequency Range | 50 Hz |
Display | 2x16 LCD |
Phase Arrangement | 3 |
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Schneider |
Current | 1/5 A |
Power Source | AC/DC |
Relay Type | Fault Protection Relays |
Mounting Type | Panel |
Number Of Poles | 4 |
Ampere Sensitivity Setting | refer manual |
Ct Ratio Programming | refer manual |
Phase | Single Phase |
The MiCOM P12x/y relays provides features for easy adaptation and are suitable for all applications where overcurrent and earth-fault protection are required.
The MiCOM P12x non-directional relays ranges from the single phase/earth fault P120 up to the multifunction three phase and earth fault P123.
The MiCOM P12y directional relays ranges from the single phase/earth fault P125 up to the multifunction three phase and earth fault P127, complete of voltage and frequency protection functions.
Users particularly appreciate the friendliness of the Human Machine Interface and the easy setting of the relays (that can be fully set through the front HMI or using MiCOM S1 setting software).
In addition to its protection function, MiCOM P12x/y provides full measurement and monitoring information necessary for efficient maintenance and post-fault analysis.
Several communication protocols allow easy interfacing of the MiCOM P12x/y relays in most of substation control or SCADA systems.
Additional Information:
Product Details:
Voltage Type | AC/DC |
Relay Type | Overload Relay |
Current (Amp) | 1A or 5A |
Nominal Voltage | 24-60 V |
Auxiliary Voltage | 24 V |
CT Input | 4 |
Opto Inputs | 8 |
Output Contacts | 8 |
MiCOM series 10 Relays fulfils the basic requirements of Buildings and small Industries applications with particular focus on overcurrent and motor protection.
Available Type:
Auxiliary powered
Self powered/dual powered
Technical Data Description:
Nominal Voltage (Vnom): 60-250 V(DC)
Nominal Voltage (Vnom): 90-240 V(AC)
Auxiliary Voltage: >90 V(AC), >90 V(DC)
Application:
Overcurrent & Earth Fault Protection.
Motor Protection
Protection Functions Available:
Thermal overload (49)
Ground fault (50/51N)
3 Phase overcurrent (50/51P)
Circuit breaker failure (50BF)
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Relay Type | Voltage Relay |
Brand | Schneider |
Voltage Type | AC/DC |
Current | 1 A to 5 A |
Number of Poles | 3 Pole |
Application | Over-current & Earth Fault Protection |
Features:
Flexible Current Relay
Full set of measurement
Easy settings
Effortless installation
Product Details:
Brand | Schneider Electric |
Number Of Poles | 3 Pole |
Type | Voltage Relays |
Frequency | 50 Hz |
Voltage | 24-240 V |
Current (Amp) | 1 A or 5 A |
Product Details:
Minimum Order Quantity | 1 Number |
Brand | Schneider Electric |
Voltage | For All Voltage Range |
Current | 1A or 5A CT |
Power Source | AC DC Both |
Relay Type | Generator Protection Relay |
Mounting Type | Panel |
Ampere Sensitivity Setting | 1/5 |
Coil Power Consumption | Very Minimum |
Number Of Poles | 3 Pole |
Ct Ratio Programming | Selectable |
Dimensions | Suitable to Front of Panel |
Frequency | 50Hz |
Model Number | Micom P341 |
Packing Type | Standard |
Display Type | LCD |
Is It CE Certified | Ce Certified |
Condition | New |
Product Details:
Model Name/Number | 7SR1002-1KA10-2CA0 |
Brand | siemens |
Voltage | AC/DC 60-240V, Binary input threshold 88 VAC/ VDC |
Usage/Application | Non-Directional Overcurrent Protection (Feeder Protection Relay) |
Product Details:
Model Name/Number | Micom Relays |
Relay Type | Over Current , Earth Fault Relays |
Voltage Type | DC |
Number Of Poles | 3 Pole |
Brand | Schnieder Electric |
Height | refer catlog |
Width | refer catlog |
Usage/Application | current monitoring |
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Schneider |
Voltage | 24V AC/DC to 230 V AC/DC |
Power Source | Electric |
Relay Type | Over Current Earth Fault |
Mounting Type | Panel |
Number Of Poles | 3 |
Product Details:
Model Name/Number | 7SR1003-2KA20-2CA0 |
Brand | siemens |
Voltage | AC/DC 60-240V, Binary input threshold 88 VAC/ VDC |
Product Details:
Model Name/Number | Micom 20 Series (P12x) |
Relay Type | Protection Relay |
Brand | Schneider |
Voltage | 230 V |
Current | 1/5A |
Voltage Type | Both AC or DC |
Usage/Application | Feeder Protection |
Display | Digital |
Frequency | 50 Hz. |
Mounting | Flush |
Voltage (V) | 24 to 250 V AC or DC |
We provide all ranges of Feeder Protection Relays.
Protection Functions:
Three-phase overcurrent (50/51) & earth overcurrent (50N/51N)
Three-phase & earth-fault directional overcurrent (67/67N)
Thermal overload (49)
High impedance restricted earth-fault (64N)
Negative sequence overcurrent (46)
High impedance three-phase differential protection (87)
Under / over voltage (27/59)
Under / over frequency (81U/O)
Rate of frequency (81R)
Circuit breaker failure protection (50BF)
Voltage controlled overcurrent (51V)
Voltage transformer supervision (VTS)
Autorecloser (79)
Undercurrent protection (37)
Directional power protection (32)
Broken conductor (46BC)
Product Details:
Minimum Order Quantity | 1 Unit |
Relay Type | Feeder Protection Relays |
Brand | Schneider |
Voltage | 1A & 5A |
Current | 1/5 A |
Voltage Type | AC |
Type | Protection Relays |
Number Of Poles | 4 |
Material | refer manual |
Height | refer manual |
Customer Benefits:
Application:
Additional Information: